Introduction to Xima L Series Crane and Hoist Drives

Xima’s specialized Crane and Hoist Drive, developed after years of experience in the lift industry, is designed with high power output and optimized current handling capabilities. Featuring advanced software and hardware, it is tailored for various applications such as elevators, escalators, cranes, and hoists. This drive has been introduced to the market with a strong focus on the three essential pillars of safety, precision, and power, ensuring optimal performance in lifting operations.

G100B075-3

Technical Specifications of Xima L Series Crane and Hoist Drives

Key Features of Xima L Series Crane and Hoist Drives

Technical Features of Xima L Series Crane and Hoist Drives

Single-Phase Input:

1.5 kW

2.2 kW

3 kW

Three-Phase Input:

1.5 kW

2.2 kW

3 kW

4 kW

5.5 kW

7.5 kW

11 kW

15 kW

18.5 kW

22 kW

30 kW

Product Code : L100B075-3

IDrive Series
II Drive Application Type
IIIDrive Size
IVDrive Power
VNumber of Drive Phases
Series ۱۰۰۱۰۰
Series ۲۰۰۲۰۰
Series ۳۰۰۳۰۰
Series ۱۰۰۱۰۰
Series ۲۰۰۲۰۰
Series ۳۰۰۳۰۰
۱۵۵*۹۵*۱۴۰Size A
۲۰۶*۱۰۳*۱۶۰Size B
۲۸۵*۱۳۲*۱۷۹Size C
۴۴۸*۲۰۵*۱۹۸Size D
۰.۳۷ (kW) ۰۰۴
۰.۷۵ (kW) ۰۰۸
۱.۱ (kW) ۰۱۱
۱.۵ (kW) ۰۱۵
۲.۲ (kW) ۰۲۲
۳ (kW) ۰۳۰
۴ (kW) ۰۴۰
۵.۵ (kW) ۰۵۵
۷.۵ (kW) ۰۷۵
۱۱ (kW) ۱۱۰
۱۵ (kW) ۱۵۰
۱۸.۵ (kW) ۱۸۵
۲۲ (kW) ۲۲۰
۳۰ (kW) ۳۰۰
Single-phase۱
Three-phase۳

Size A : 140
Size B : 160
Size C : 197
Size D : 198

Size A : 95
Size B : 103
Size C : 132
Size D : 205

Size A : 155
Size B : 206
Size C : 285
Size D : 448

Size A : 144
Size B : 194.5
Size C : 269.5
Size D : 426

Size A : 84
Size B : 91.5
Size C : 115
Size D : 159

Dimensions of Xima Drives

The adjacent figures illustrate the drive dimensions from different angles.

Front Panel of Xima Drives
Xima Touch Proprietary Software
General Schematic of Xima L Series Drives

In this image, you can become familiar with the various parts of the Series (L) panel.

By clicking on different items, you can view their descriptions.

LCD

A 4-digit display for showing frequency, speed, current, load value, and for viewing and adjusting parameters.

LCD
صفحه‌نمایش ۴ رقمی و برای نمایش مقادیر فرکانس، دور، جریان، مقدار بار و مشاهده و تنظیم پارامترها.

LED
چهار عدد LED برای نمایش جهت چرخش موتور، نمایش جریان یا درصد بار، فرکانس یا دور موتور، استارت یا استپ بودن دستگاه.

START/DIR کلید استارت و تغییر جهت (START/DIR). در صورت انتخاب کنترل از صفحه‌کلید توسط پارامتر  این کلید برای استارت کردن موتور به کار می‌رود. درصورتی‌که مقدار پارامتر   برابر  باشد با نگه‌داشتن این کلید به مدت ۲ ثانیه در حالتی که دستگاه استارت است، جهت موتور برعکس خواهد شد. (توضیحات بیشتر در  و )
RESET/STOP کلید استپ و ریست(RESET/STOP) . در صورت انتخاب کنترل از صفحه‌کلید توسط پارامتر  این کلید برای استپ کردن دستگاه به کار می‌رود و در مواقع بروز خطا برای ریست کردن خطا نیز به کار می‌رود. نگه‌داشتن این کلید به مدت ۲ ثانیه، خطای رخ‌داده را ریست می‌کند. (خطای اتصال کوتاه یا  با این کلید ریست نمی‌شود و دستگاه باید خاموش و روشن شود) توجه کنید که اگر خطایی مکرراً رخ می‌دهد از ریست کردن آن خودداری نموده و حتماً با شرکت تماس حاصل نمایید تا از خرابی کلی دستگاه جلوگیری به عمل آید.

NEXT/INCPREV/DEC
کلید افزایش/بعدی (NEXT/INC) و کلید کاهش/قبلی (PREV/DEC). در هنگام تنظیم پارامترها برای حرکت روی پارامترهای مختلف و یا تغییر مقدار یک پارامتر (در صورت انتخاب شدن پارامتر) به کار می‌رود. در ادامه توضیحات بیشتر را مشاهده خواهید نمود.

ENTER کلید Enter برای رفتن به صفحه پارامترها به و یا انتخاب و ذخیره یک پارامتر و یا اجرای فرمان‌هایی مثل تنظیم خودکار و برگرداندن پارامترها به کار می‌رود.در ادامه توضیحات بیشتر را مشاهده خواهید نمود.
BACK کلید خروج (Back) که برای خروج از هر مرحله در هنگام تنظیم پارامترها به کار می‌رود.

DISP (G۲۰۰)
حالت صفحه نمایش را تغییر می‌دهد.

P۱/RESET (G۲۰۰)
رزرو شده.

XIMA Touch Dedicated Software

Technical Specifications

Product Model

Power (kW)

Power (HP)

Dimensions (mm)

SizeWeight
L100B015-11.52206 * 103 * 160B

Less than 2200 grams

L100B015-31.52206 * 103 * 160B

Less than 2200 grams

L100B022-12.23206 * 103 * 160BLess than 2200 grams
L100B022-32.23206 * 103 * 160BLess than 2200 grams
L100B030-134206 * 103 * 160BLess than 2200 grams
L100B030-334206 * 103 * 160BLess than 2200 grams
L100B040-345.5206 * 103 * 160BLess than 2200 grams
L100B055-35.57.5206 * 103 * 160BLess than 2200 grams
L200C075-37.510285 * 132 * 179CLess than 3600 grams
L200C110-31115285 * 132 * 179CLess than 3600 grams
L200C150-31520285 * 132 * 179CLess than 3600 grams
L300D185-318.525448 * 205 * 198DLess than 10,800 grams
L300D220-32229.5448 * 205 * 198DLess than 10,800 grams
L300D300-33040448 * 205 * 198DLess than 10,800 grams

Product Model

Power (kW)

Input Voltage

Output Voltage

Input Current (A)Output Current (A)
L100B015-11.5

 220 V
Single-phase
50–60 Hz

220 V
Three-phase
0–800 Hz
18.59
L100B015-31.5380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
5.45
L100B022-12.2220 V
Single-phase
50–60 Hz
220 V
Three-phase
0–800 Hz
2211
L100B022-32.2380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
7.67
L100B030-13220 V
Single-phase
50–60 Hz
220 V
Three-phase
0–800 Hz
34.716.5
L100B030-33380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
9.79
L100B040-34380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
10.810
L100B055-35.5380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
14.213
L200C075-37.5380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
2119
L200C110-311380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
28.926
L200C150-315380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
40.336
L300D185-318.5380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
4540
L300D220-322380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
5447
L300D300-330380 V
Three-phase
50–60 Hz
380 V
Three-phase
0–800 Hz
7263

PWM Frequency

2 – 10 kHz

Analog Voltage Input Impedance

14.3 kΩ

Analog Current Input Impedance

150 Ω

Digital Input Impedance

9.5 kΩ

Efficiency

% 97.5

Number of Inputs and Outputs

8 Digital Inputs

    

Enclosure Standard

IP 20

Body Structure

Compressed Plastic and Metal

Accessories Included

Catalog

Screws and Washers

Template

Small Screwdriver یا Small Phillips Screwdriver

RS-485 Port

Includes (one LAN port and one Serial port)

Detachable Keypad

Coming Soon

Country of Origin

Iran

    
Display

4 Seven Segments

4 LEDs

Keypad

6 (8) Keys

Output Frequency Range

0-800 Hz

Frequency Resolution

0.001 Hz (0.1 Hz display)

PWM Frequency

2.0 – 10.0 KHz

PWM Modulation

Space Vector

PWM Resolution

> 11bit

ADC Resolution

12 bit / 4 Msps

DSP

32 bit Motor Control

Control Sampling Frequency

1000 Hz

Input Frequency

47-63 Hz

Input Voltage

200 – 260 (1PH)

330 – 460 (3PH)

Output Voltage

0 – Input Voltage

Efficiency (PF=1 , Vout=Vin)

> %97.5

Phase Short Circuit Protection

To phase

Ground

+Bus

-Bus

Brake

DC Brake

Dynamic Brake

Voltage Limit Threshold (if enabled)

380 V (1PH)

700 V (3PH)

Brake ON Voltage

370 V (1PH)

690 V (3PH)

Brake OFF Voltage

365 V (1PH)

680 V (3PH)

Over Voltage Fault

400 V (1PH)

720 V (3PH)

Current Limit Threshold

Adjustable

Over Current Threshold

2x Drive Rated Current

Analog Voltage Input Impedance

14.3 Kohm

Analog Current Input Impedance

150 ohm

Digital Input Impedance

9.5 Kohm

12V Output Voltage

12-14 V

12V Supply Output Impedance

5 ohm (PTC protected)

Torque Control Response

< 200ms

Start Torque

150% Rated Output Torque

0.5 Hz

Torque Control Precision

± 0.5% Rated Output Torque

Ambient Temperature

-10 < Ta < 50 C

Humidity

< %85

Altitude

Below 1000m Without Derating

Vibration

0.5 g X, Y, Z

Stall Prevention

Acceleration

Deceleration

Operation

Overcurrent

180% Rated Current For 30 s

Overload Warning

150% Rated Current For 1 min

Motor Thermal Protection

Overload Curve

Overload Curve

VDC > 750 V (380V Class)

VDC > 390 V (220V Class)

Undervoltage

VDC < 350 V (380V Class)

VDC < 200 V (220V Class)

Overheat

Protection By Thermistor

Grounding

Protection By DC Current Sensor

Phase Loss

Input – Output

Momentary Power Loss

10ms at Nominal Voltage and Power

Applications and Uses of the L Series Products

Motor drives or speed controllers are used to enable soft starting and precise speed regulation of AC motors (both single-phase and three-phase) across various industries. These drives can continuously vary the motor speed from zero up to several times the motor’s rated speed. Speed control in electric motors not only increases the flexibility of industrial processes but also plays a significant role in energy savings by reducing starting current and optimizing motor control.

Xima’s L Series drives, featuring high current capacity and an intelligent learning algorithm for motor model identification, are available in 11 different models. They are widely applied in various sectors, including hoists, elevators, escalators, cranes, and more.

Elevator

Crane

Hoist

Escalator